Product Identification

Product ID:1680 AEROSOL MP MICRO PROCESSOR CLEANER
MSDS Date:08/30/1993
FSC:6850
NIIN:00F009556
MSDS Number: BWTFK

Responsible Party
TECH SPRAY INC
88 HUGHES ST
AMARILLO, TX 79105-0949
US

Emergency Phone: 806-372-8523/800-858-4043

Info Phone: 800-858-4043/806-372-8523

Preparer: B RIFFEL

Cage: DO677

Contractor
TECH SPRAY INC
949 AMARILLO, TX 79105-0949 US

Telephone: 806-372-8523

Cage: DO677

Ingredients

FREON 113, 1,1,2,-TRICHLORO-1,2,2,-TRIFLUOROETHANE,

CAS: 76-13-1

RTECS: KJ4000000

Fraction By Weight: 80%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


CHLORODIFLUOROMETHANE, FREON 22, MONOCHLORODIFLUOROMETHANE

CAS: 75-45-6

RTECS: PA6390000

Fraction By Weight: 18%

OSHA PEL 1000 PPM

ACGIH TLV: 3540 MG/CUM


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: <2%

OSHA PEL 5000 PPM

ACGIH TLV: 9000 MG/CUM

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: VAPORS CAN CAUSE
SUFFOCATION BY REDUCING THE AVAILABLE OXYGEN FOR BREATHING, MAY
LEAD TO DEATH. EYES: SLIGHT, TEMPORARY IRRITATION W/CORNEAL INJURY.
INGESTION: SINGLE DOSE TOXICITY IS LOW TO MODERATE. IF VOMITING
OCCURS, LIQUIDASPIRATED INTO LUNGS CAN CAUSE CHEMICAL PNEUMONIA &
SYSTEMIC EFFECTS. (SEE SUPP)
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SUFFOCATION, LIGHT-HEADEDNESS, GIDDINESS,
SHORTNESS OF BREATH, CONFUSION, NARCOSIS, CARDIAC IRREGULARITIES,
UNCONSCIOUSNESS, IRRITATION, DEFATTING, VOMITING

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR. IF BREATHING HAS STOPPED,
ADMINISTER CPR. EYES: FLUSH FOR 15 MINS W/CLEAR WATER. SKIN: WASH
W/SOAP & WATER. INGESTION: ASPIRATION HAZARD. DON'T INDUCE
VOMITING. GIVE 2 GLASSES OF WATER. OBTAIN MEDICAL ATTENTION IN ALL
CASES. NOTE: ADRENALIN & OTHER SIMILAR CARDIAC STIMULANTS SHOULDN'T
BE USED TO TREAT EFFECTS OF OVEREXPOSURE TO THIS PRODUCT.

Fire Fighting

Flash Point Method:TCC
Flash Point:NONE
Extinguishing Media:WATER, FOAM, DRY CHEMICAL, CO2
Fire Fighting Procedures:WEAR SELF CONTAINED POSITIVE PRESSURE
BREATHING APPARATUS & AVOID SKIN CONTACT.
Unusual Fire/Explosion Hazard:AEROSOL CANS MAY ERUPT W/FORCE AT
TEMPERATURES >120F.

Accidental Release

Spill Release Procedures:EVACUATE & VENTILATE AREA. AVOID BREATHING
VAPORS. VAPOR CONCENTRATION WILL BE HIGHEST ALONG FLOOR & IN LOW
LYING AREAS. PICK UP LIQUID ON SUITABLE ABSORBENT & STORE IN SEALED
CONTAINERS.

Handling

Handling and Storage Precautions:KEEP AEROSOL CANS IN COOL PLACE OUT OF
DIRECT SUNLIGHT. KEEP THIS & ALL CHEMICALS OUT OF REACH OF
CHILDREN. THIS PRODUCT IS FOR INDUSTRIAL USE ONLY.
Other Precautions:AVOID BREATHING VAPORS.

Exposure Controls

Respiratory Protection:IF LEVELS EXCEED TLV, INCREASED
VENTILATION/ORGANIC VAPOR MASK IS REQUIRED.
Ventilation:REQUIRED. DON'T USE IN CLOSED SPACE.
Protective Gloves:NEOPRENE/POLYVINYL ALCOHOL
Eye Protection:SPLASH PROOF SAFETY GOGGLES/GLASSES
Supplemental Safety and Health
HEALTH HAZ CONT'D: INGESTION-HUMAN PSYCHOTROPIC, GASTROINTESTINAL &
CENTRAL NERVOUS SYSTEM EFFECTS ARE POSSIBLE.

Chemical Properties

Boiling Pt:B.P. Text:116F
Vapor Density:6.5
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR WATER-WHITE MOBILE LIQUID W/SLIGHT ETHEREAL
ODOR
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
ALKALI METALS, STRONG ACIDS & BASES
Stability Condition to Avoid:OPEN FLAME, HEAT, DIRECT SUNLIGHT, TEMP
>120F
Hazardous Decomposition Products:HYDROGEN CHLORIDE, PHOSGENE, CHLORINE,
CO2, CO

Disposal

Waste Disposal Methods:MATERIAL MAY BE DISPOSED OF BY A LICENSED
RECLAIMER/INCINERATION FACILITY. DON'T INCINERATE/DESTROY AEROSOL
CANS. DISPOSE OF IN ACCORDANCE W/LOCAL, STATE & FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.